CODE: RESP0043 | ΕΑΝ: 00619498368105 | Part No: 36810
Fits every ResMed machine — S9, AirSense 10 and 11, AirCurve, Lumis and AirStart
15 mm inner diameter instead of 19 mm — 40% lighter than standard tubing, per ResMed
Less weight pulling at the mask when you turn over — fewer leaks caused by movement
Set the machine after you fit it — Settings, Accessories, Tube, SlimLine
Not a heated tube — for condensation in the mask you want a ClimateLineAir
Buy now, pay later in 3 interest-free installments for purchases over €35. Read more.
Ships in 1-3 days
Fits every ResMed machine — S9, AirSense 10 and 11, AirCurve, Lumis and AirStart
15 mm inner diameter instead of 19 mm — 40% lighter than standard tubing, per ResMed
Less weight pulling at the mask when you turn over — fewer leaks caused by movement
Set the machine after you fit it — Settings, Accessories, Tube, SlimLine
Not a heated tube — for condensation in the mask you want a ClimateLineAir
Description
1.8 m SLIM TUBING · ResMed SlimLine 15 mm
You turn over and the mask breaks its seal. Very often it is the tube.
Standard 19 mm tubing is thick and heavy. It hangs off the side of the bed, and every time you turn, its weight drags the mask sideways. The SlimLine is 15 mm and, on ResMed's own figures, 40% lighter — it follows your movement instead of fighting it.
1.8 m
length
15 mm
inner diameter
85 g
weight
✅ S9 · AirSense 10 & 11 · AirCurve · Lumis🪶 40% lighter (ResMed)📏 1.8 m · 15 mm🚚 Dispatch in 24–48h⚙️ Set the tube to “SlimLine”
The same pressure at the mask, less air inside the tube. The 15 mm bore is what makes the SlimLine lighter and more flexible than the standard 19 mm.
THE REAL PROBLEM
It is not always the mask.
It is what hangs off it.
A 19 mm tube full of air is not heavy when you hold it in your hand — it is heavy when it hangs off the side of the bed at three in the morning. You turn over, its weight follows half a second later, and it pulls the mask sideways. The seal breaks for a second or two, air escapes with a whistle into your eye, and you wake up. Most people respond by tightening the straps — which is how the next morning brings face marks, a headache and more leaks rather than fewer: an over-tightened mask distorts, and a distorted cushion seals worse.
Less weight on the mask, not tighter straps
The SlimLine has a 15 mm inner diameter instead of 19 mm. On ResMed's own figures that makes it 40% lighter and 20% thinner than standard tubing, and lets it take up 35% less space. Less mass to move means less pull on the mask seal when you turn over — and the straps can stay where they are supposed to be. The 22 mm ends are the standard cuff, so it connects to any CPAP mask. Only one thing is needed after fitting it: Settings → Accessories → Tube → SlimLine, so the machine knows what it is wearing.
Which machines it fits
The opposite of the heated ClimateLineAir applies here. The SlimLine has no electrical connector — just plain 22 mm ends — which is exactly why it fits every ResMed generation, from the S9 to the AirSense 11.
YES, IT FITS
✓ResMed S9 (whole range)
✓ResMed AirSense 10 (AutoSet · Elite · CPAP)
✓ResMed AirStart 10
✓ResMed AirCurve 10 (VAuto · ST · S · ASV)
✓ResMed Lumis (100 · 150 VPAP ST)
✓ResMed AirSense 11 · AirCurve 11
✓Any CPAP mask with a standard 22 mm cuff
NO — WHAT IT DOES NOT DO
✗ResMed AirMini — it uses its own tubing system
✗It is not heated — no Climate Control
✗It does not solve condensation (rainout) — a ClimateLineAir does that
✗Other manufacturers' machines — the 22 mm ends fit, but there is no “SlimLine” setting in their menus
In practice
1
Tube type setting
After fitting, select SlimLine on the machine (Settings → Accessories → Tube). ResMed's clinical guide asks that the tubing type in use be selected, and gives different flow figures for Standard and SlimLine.
2
Cleaning
Once a week, by hand, in warm water with a little dishwashing liquid. Rinse thoroughly and dry away from sunlight and radiators.
3
Not permitted
Dishwasher and washing machine. Also bleach, chlorine, aromatic solutions, antibacterial soaps and scented oils — they degrade the material and shorten its life.
4
Inspection & replacement
Inspect regularly for holes, tears, cracks and sections that have lost their shape. Replace on any visible deterioration — a small leak spoils the pressure without showing up anywhere.
Four things worth knowing
🪶
40% lighter, on ResMed's figures
15 mm instead of 19 mm, around 85 grams. What matters is not the weight itself but how much it tugs at the mask when you turn over.
🔗
One tube for the whole range
S9, AirSense 10, AirSense 11, AirCurve 10 and 11, Lumis, AirStart. If you have changed generation or keep two machines, the spare part stays the same.
⚙️
The machine has it as a setting
ResMed's clinical guide lists three tube types and asks that the one in use be selected — with different flow figures given for each.
✅
Genuine ResMed 36810
The number on the box is ResMed's own part number. The AirCurve 10 and the Lumis 150ST are supplied with this tube in the box.
Four things people ask before ordering
🔄
“Do I have an AirSense 10 or an 11?”
Here it does not matter. The same tube fits both — and the S9, the AirCurve and the Lumis.
⚙️
“Do I need to change anything on the machine?”
Yes, one thing: Settings → Accessories → Tube → SlimLine. Otherwise the machine still thinks it has standard tubing.
🌡
“Will it stop the water in the mask?”
No. It is not heated. For condensation you need a ClimateLineAir.
🧼
“Can it be washed?”
Yes — it has no electrical components. By hand, once a week. No dishwasher.
Technical specifications
📏 Length
1.8 m (6 ft) · 22 mm connection ends
⭕ Inner diameter
15 mm — ResMed's standard tube is 19 mm
⚖️ Weight
85 g · approximate, unpackaged
🪶 Versus standard tubing
40% lighter · 20% thinner · 35% less space — ResMed figures
By condition — on any crack, tear, discolouration or loss of shape
🧪 Material
Plastic, reusable · no electrical components
🏭 Manufactured by
ResMed Pty Ltd, Australia
🔢 Part number
ResMed 36810 · SKU RESP0043 · EAN 0619498368105
Genuine ResMed
Part number 36810
Dispatch 24–48h
Tracked courier delivery
Fits every ResMed
From the S9 to the AirSense 11
Just ask
Send us a photo of your device
Compliance and safe use
Medical device. The following applies to every unit Traumacare ships.
Manufacturer
ResMed Pty Ltd, 1 Elizabeth Macarthur Drive, Bella Vista NSW 2153, Australia
Regulatory status
A genuine ResMed accessory for the company's PAP systems. The tube falls under Regulation (EU) 2017/745in its own right: accessories to medical devices are regulated as devices themselves. The CE marking details, the legal manufacturer and the batch number are given on the packaging and in the instructions for use supplied with it. This tube is not heated and does not provide Climate Control — it does not replace a heated tube where one has been prescribed. After fitting, the tube type must be declared on the machine (Settings → Accessories → Tube → SlimLine) in line with the manufacturer's instructions. Replace it immediately if a crack, tear or discolouration appears. EU authorised representative: ResMed SAS, 292 Allée Jacques Monod, 69791 Saint-Priest, France.
Instructions for use
Supplied in print inside the box, in Greek. Read them before first use and keep them for as long as you own the device.
Batch and traceability
The batch number (LOT) of the unit we ship you is recorded on your invoice. If the manufacturer ever recalls a batch, we know exactly who to contact.
Returns
A sealed product that, for hygiene reasons, cannot be returned once unsealed. Sealed and intact, it is returnable as normal — returns policy.
Reporting a problem
If anything is wrong with the packaging, the labelling or the way the device works, get in touch or write to [email protected]. We log every report and pass it to the manufacturer.
This page is a commercial description of the product. It does not replace the manufacturer’s instructions for use, or the advice of your doctor or nurse.
See these too
The tube is one of three CPAP consumables. The other two are the water tub and the filter — and they need replacing as well.
the parent category, with devices, masks and consumables
Frequently asked questions
Will it fit my machine?
Almost certainly, if it is a ResMed. The SlimLine has no electrical connector — just plain 22 mm ends, which are the standard cuff. That is why it fits the whole range: S9, AirSense 10 (AutoSet, Elite, CPAP), AirStart 10, AirCurve 10 (VAuto, ST, S, ASV), Lumis, AirSense 11 and AirCurve 11. It is the exact opposite of the heated ClimateLineAir, where the electrical connector locks the tube to one generation. The exception is the AirMini, which uses its own tubing system.
Do I need to change anything on the machine after fitting it?
Yes, one thing, and it is the most commonly missed step: Settings → Accessories → Tube → SlimLine. ResMed's clinical guide for the AirSense 10 lists three options — ClimateLineAir (detected automatically), SlimLine and Standard — with the instruction to “select the type of air tubing used by the patient”. This is not a cosmetic setting: the same guide gives different maximum flow rates at each pressure for Standard and SlimLine, because a 15 mm tube and a 19 mm tube do not behave the same. If you are unsure, send us a photo of the screen.
What is the difference from standard tubing?
The bore. ResMed's standard tube has a 19 mm inner diameter; the SlimLine has 15 mm. ResMed's own figures make it 40% lighter and 20% thinner, taking up 35% less space. On the scales that comes to roughly 85 grams. The number that matters is not the weight itself but how much it tugs at the mask when you turn over: less mass to move means less pull on the seal.
Will it stop the water that collects in the mask?
No. The SlimLine is not heated and does not provide Climate Control. Water in the mask is condensation, or rainout, and what solves it is a heated tube holding the wall warm along its whole length — the ClimateLineAir 11 (part 39104) for the 11 series, or the ClimateLineAir (37296) for the 10 series. The SlimLine solves a different problem: the weight and bulk of the tube.
Can it be washed? How often should it be replaced?
It can, and more easily than a heated tube, because it has no electrical components inside it. Once a week, by hand, in warm water with a little dishwashing liquid; rinse thoroughly and dry away from direct sunlight. No dishwasher and no washing machine, and no bleach, chlorine, aromatic solutions, antibacterial soaps or scented oils. For replacement the rule is condition rather than calendar: change it as soon as you see a crack, a tear, discolouration or a section that has lost its shape — a small leak spoils the pressure without showing up anywhere.
I have two machines, one at home and one for travel. Do I need two different tubes?
If both are ResMed S9 or newer, no — the same part, 36810, fits both. The same holds when you change generation: a patient moving from an AirSense 10 to an AirSense 11 keeps the same tube, whereas a heated tube would have to be replaced. Just remember to set SlimLine on both machines. The AirCurve 10 and the Lumis 150ST are in fact supplied with this tube in the box.
Fill out the form below and we will contact you immediately to guide you through the purchase process through EOPYY.
Back
Welcome to Traumacare
We ask for your permission to use your personal data.
Personalized ads and content, ad and content measurement, audience insights, and product development.
Store information on your device.
Learn more
Your personal data will be processed and information from your device (cookies, unique identifiers and other device data) may be stored, accessed and shared with third party vendors or used specifically by this website or app.
Some vendors may process your personal data based on legitimate interests, to which you may object by managing your choices below. Look for a link at the bottom of this page or in our privacy policy where you can withdraw your consent.